Products  | Support & Services  | News & Events  | Partners  | Policies  | Global Sites
Home > Support > Open Text Connectivity Products > Exceed >  How are dynamically allocated display numbers released and reallocated? Print View   Contact Me
Connectivity Support


How are dynamically allocated display numbers released and reallocated?

LAST MODIFIED DATE: June 15, 2005

VERSION: This applies to Exceed version 10.0

PROBLEM:

After a person disconnects from the Windows Terminal Server, how long before the display becomes available for a new user?

SOLUTION:

Edit the Display Manager.ini file in in Document and Settings\All Users\Application Data\Hummingbird\Connectivity\10\Global\Exceed:

Display Sync Interval = 0

By default 0 means no automated synchronization is arranged.

When it is set to 1, it means each time before a new display number is to be assigned, the Controller synchronizes its internal data with display numbers used in the real world. However, as a result, the response time of the Controller service will increase.

If it is set to N ( N = 2, 3, 4, ... ), the Controller will synchronize itself after N display numbers has been assigned, repeatedly.

For example:
Display Sync Interval = 5
After 5 displays has been assigned the Controller service will synchronize, and any released displays will now be available.